TRANSPONDER-CODED READ HEADS WITH EXTERNAL EVALUATION

READ HEADS CES

Description

The read head is fastened to the fixed part of the guard and is connected to the evaluation unit via a two-core screened cable. The actuator fastened to the guard is moved towards the read head by closing the door. When the switch-on distance is reached, power is supplied to the actuator via the read head and the read head transfers the actuator’s data to the evaluation unit.


READ HEADS CEM

Description

  • With transponder coding
  • Integrated mounting magnet (without guard lock monitoring)
  • Up to Category 4 / PL e according to EN ISO 13849‑1 for monitoring the position of the guard
  • Adjustable adhesive force optional

READ HEADS CET-AX

Description

  • Read head with guard locking and guard lock monitoring
  • Up to Category 4
  • High locking forces up to 6,500 N
  • Integrated transponder coding
  • Metal housing

CKS KEY ADAPTER

Features

  • Starting dangerous machine movements is not possible when the key is withdrawn
  • Suitable for the highest safety requirements: Cat. 4 / PL e
  • Every key is unique
  • High level of protection against tampering

FIELD EVALUATION UNIT CES-FD

Benefits for you

  • Maximum safety with Cat. 4/PLe
  • Minimal wiring effort
  • Small space requirement
  • No additional rail mounted evaluation unit required

EVALUATION UNITS CES-AZ

  • Monitoring outputs
  • Start button
  • Feedback loop
  • Unicode or multicode evaluation units
  • Guard locking monitoring